PhD Lite
Multi-Gas Detectors
Most Common PhD Lite
Accessories
P
ART NO. DESCRIPTION
54-26-0101 Continuous sample pump for
PhD Lite. Includes 10' of
sample tubing and sample
probe assembly.
54-26-0101-C Continuous sample pump for
P
hD Lite – Configured for reac-
tive gas detection, such as Cl
2
and ClO
2
. Includes 10' of inert
sample tubing and sample
probe assembly.
54-26-0302 Leather holster. For PhD Lite
without pump.
54-26-0306 Leather holster
. For PhD Lite
with pump attached.
54-26-0603 PhD Lite BioTrak Software Kit.
Includes BioTrak software and
manual.
54-26-0605S Infrared communication device
(Serial – IrDA) – Requires one
available PC serial port.
54-26-0605U Infrared communication device
(USB – IrDA) – Requires one
available USB port.
54-27-0802 TouchID
™
programming kit.
Includes software, program-
ming wand, serial connector,
10 TouchID
™
buttons, 10 key
chain / wall mounts for buttons
and 10 TouchID
™
badges.
PhD Lite Smart Sensors
P
ART NUMBER DESCRIPTION RANGE RESOLUTION
54-25-80 LEL Combustible Gas 0 – 100% LEL 1% LEL
54-25-90 O
2
Oxygen 0 – 30% / Vol. 0.1%
5
4-25-01
C
O Carbon Monoxide 0 – 1000 PPM 1 PPM
54-25-05 CO+ CO Plus dual purpose CO/H
2
S CO: 0 – 1000 PPM 1 PPM
(provides a non-specific H
2
S: 0 – 200 PPM 1 PPM
r
eadout for CO and H
2
S
)
54-25-19 CO-H CO Minus, reduced sensitivity 0 – 1000 PPM 1 PPM
to H
2
54-25-02 H
2
S Hydrogen Sulfide 0 – 200 PPM 1 PPM
54-25-14 Duo-Tox Dual Channel CO/H
2
S CO: 0 – 1000 PPM 1 PPM
(provides Substance specific H
2
S: 0 – 200 PPM 1 PPM
readouts for CO and H
2
S)
54-25-03 SO
2
Sulfur Dioxide 0 – 25 PPM 0.1 PPM
54-25-15 SO
2
-Ext. Sulfur Dioxide extended range 0 – 100 PPM 1 PPM
54-25-04†NH
3
Ammonia 0 – 50 PPM 1 PPM
(for software versions
prior to 2.0)
54-25-21† NH
3
Ammonia 0 – 100 PPM 1 PPM
54-25-08† †† Cl
2
Chlorine (non-specific) 0 – 50 PPM 0.1 PPM
54-25-18† †† Cl
2
Chlorine (specific) 0 – 50 PPM 0.1 PPM
54-25-12† †† ClO
2
Chlorine Dioxide (non-specific) 0 – 15 PPM 0.1 PPM
54-25-20 ClO
2
Chlorine Dioxide (specific) 0 – 5 PPM 0.01 PPM
54-25-06 NO Nitric Oxide 0 – 350 PPM 1 PPM
54-25-09†NO
2
Nitrogen Dioxide 0 – 50 PPM 0.1 PPM
54-25-10† HCN Hydrogen Cyanide 0 – 100 PPM 0.2 PPM
54-25-13 PH
3
Phosphine 0 – 20 PPM 0.1 PPM
† Special reactive gas calibration adapter (54-26-0405) required for proper calibration.
††
The non-specif
ic Cl
2
and ClO
2
sensors can be used for the detection of both gases.
The specif
ic Cl
2
and ClO
2
sensors are designed for the target gas only
.
15